Wondfo is a globally recognized fast growing POCT company devoted to R&D, manufacture and sales of rapid diagnostic reagents and medical devices in IVD field. Apart from the Guangzhou headquarters, Wondfo also owns one overseas lab in San Diego, one branch in Chicago and several overseas offices.“Quality is life!” is paramount in everything we do. Wondfo has won good reputation worldwide by providing premium products and professional services. We aim at serving the public, and hence people will trust Wondfo.
Wondfo Sperm Concentration Test is a rapid test for qualitative detection of sperm concentration in human semen, as an aid in the determination of a man’s fertility status.
HOW TO DO THE TEST?
1.Gently shake the collection cup with semen then let the sample standing for at least twenty(20) minutes, but no more than 60 minutes for the semen to become thin (liquefied) before testing (The semen sample is too thick for test immediately after ejaculation).
2. Gently stir the sample in the collection cup with the semen transfer device for 10 times.
3. Unscrew the cap of the solution bottle. Transfer 0.1 mL of the sample into the solution bottle with the semen transfer device, avoid any bubbles.
4. Screw the cap of solution bottle tightly and gently mix the sample thoroughly. It's recommended to turn the solution bottle upside down for 5-10 times.
5. Let the solution bottle standing for 2 minutes.
6. Remove the testing cassette from the sealed pouch by tearing at the notch and place the testing cassette on a flat surface.
7. Unscrew the smaller cap of the solution bottle, and add 2 full drops of the semen sample on the sample well of the cassette vertically.
8. Wait for 5-10 minutes and read the result. Do not read results before 5 minutes or after 10 minutes.
HOW TO READ THE RESULTS?
Positive (+) Colored bands are visible in both the control region (C) and the test region (T). It indicates a positive result (the sperm concentration ≥15×106/mL).
Negative (-) A colored band is visible only in the control region (C). No color band appears in the test region (T). It indicates a negative result (the sperm concentration <15×106/mL).
Invalid
No visible band at both region, or there is a visible band only in the test region but not in the control region. Repeat with a new test cassette.
Please make sure the adding sample volume is enough. If the test still fails, please contact Wondfo or the distributor for technical assistance.
STORAGE AND STABILITY
1. Store at 4°C~30°C in the sealed pouch up to the expiration date.
Shelf life is up to 24 months.
2. Test cassette should be used within 1 hour after opening the pack.
3. Keep away from sunlight, moisture and heat.
4. Do not freeze.
Specification:
CODE#: W121-C
Strip size: 4.0MM Weight: 0.2KG/box
Content:
1. One test in one pouch. Each pouch contains a test cassette, a desiccant. (The desiccant is for storage purposes only, and is not used in the test procedures.)
2.One semen transfer device, one semen collection cup.
3. One bottle of buffer solution.
4.Leaflet with instructions for use.
PRECAUTIONS:
1. The best collection time should be 2 to 7 days from the last ejaculation, collect semen in shorter than 2 days or longer than 7 days will affect the accuracy of the test results.
2. The test cassette is disposable. Do not reuse the test cassette.
3. Do not use the test cassette beyond the expiration date.
4. Do not use the test cassette if the pouch is punctured or not well sealed.
5. Please use flesh semen sample. Do not use any lubricants or lotions, and do not collect semen from condom which may influence the test result.
6. The result can’t reflect the quality of the semen if only part of semen is collected or some of the semen is spilled out.
7. The sample should be liquefied semen; the semen liquefaction process should be no more than 60 minutes. If the sample is not completely liquefied within 60 minutes, it is considered abnormal.
8. High testing temperature should be avoided.
9. The results should be interpreted by physicians along with clinical features and other laboratory test results. For any problem or suggestion, please contact the manufacturer.