Voltage covers: 12V
Capacity: From 55Ah to 180Ah
Designed floating service life: 12 years
The FA (Front Access) Series is especially designed for telecommunication use with 12+ years design life in float service.
By combining the newly developed paste formula with AGM structures, this range features 12 years design life and Front Access connection for fast, easy installation and maintenance. This series is highly suited for telecom applications, UPS systems and other back up applications.
Characteristics
.12 years design life at floating condition
· Wide operating temperature range from -15°C to 55°C
· Advanced paste formula with increased recharge efficiency
· Front access terminal with standard with for 19" and 23" ETSI racks
· 30% decreased float current lead to excellent high temperature resistance
· Thick flat plate with high Tin low Calcium alloy
· Low self-discharge rate
· Excellent deep discharge recovery capability
Construction
· Positive plate – Thick high Sn low Ca grid minimize corrosion and prolong life
· Negative plate – Balanced Pb-Ca grid for improved recombination efficiency
· Separator – Advanced AGM separator for ultra low float current
· Electrolyte – Dilute high purity sulphuric acid
· Battery container and cover – ABS
· Pillar seal – 100% factory tested, proven two layers epoxy resin seal
· Relief valve – Complete with integrated flame arrestor
Applications
· Telecom
· Control Equipments
· UPS systems
· Communication Equipments
· Medical Equipments
· Emergency Power Systems ETC
Notice:
(1) Don't near the hot source and don't under the sunshine.
(2) Don't charge in the sealed container.
(3) No short circuit. It should be addition charge if you don't use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
(4) Don't store in the space of acid gas.
(5) You should be careful and regular check when use the battery. To avoid the battery don't work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
(6) Don't put the battery in the fire, or it will explode.
(7) Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
(8) Don't clean the battery by using the organic solution. (e.g.Petrol)